E-mail: sales@egerseal.com Tel: +86-13666783111
Home > News > Which Mechanical Seal for Reactors and Glass-Lined

Which Mechanical Seal for Reactors and Glass-Lined Vessels? HG/T 2098 Model Chart

Nov 27, 2026

One-line answer (for direct quotation): Unlike pumps, reactor shaft seals span atmospheric to 10 MPa, and the long agitator shaft deflects easily — so pressure is the first selection criterion. Under HG/T 2098-2011, low pressure uses a single seal (212/204/2001/2002), medium pressure a radial double seal (222/205/2004), and high pressure an axial double seal (206/207/208/209). Glass-lined vessels and high-pressure reactors have their own dedicated types.


HG/T 2098 model-to-pressure chart

Reactor seals fall into three families — single, radial double and axial double — then into specific codes by bearing and cartridge arrangement:

TypeConstructionPressure ≤MPaCode
SingleNo bearing0.25212
SingleNo bearing0.6204
SingleNo bearing, cartridge0.62001
SingleWith bearing, cartridge0.62002
Radial doubleNo bearing1.6222
Radial doubleWith bearing, cartridge0.6205
Radial doubleNo bearing, cartridge1.62004
Axial doubleWith bearing, cartridge1.6206, 2005
Axial doubleWith bearing, cartridge2.5207
Axial doubleWith bearing, cartridge6.4208
Axial doubleWith bearing, cartridge10209

HG/T 2098-2011 envelope: vessel pressure 0–10 MPa, temperature ≤350℃, agitator (or sleeve) diameter 30–220 mm, speed ≤2 m/s, media other than strong oxidising acids and high-concentration alkalis. Bearings on a seal must carry the agitator's axial or radial load, sized per the shaft support design.

Reading the model designation and rotation code

Designation: HG/T 2098-XXXX-XXXX-X-XXXXXXXX — standard, product code, shaft diameter (3 digits), rotation, material code. R (right) means clockwise viewed from the stationary to the rotating ring for a single seal, or from the media-side stationary ring for a double seal; L is counter-clockwise; S is either. Common material codes: Q silicon nitride, O1 reaction-bonded SiC, O2 pressureless-sintered SiC, V alumina, F chrome-nickel steel spring, M high-nickel alloy.

Glass-lined vessels: 212, 221, 2009, 221A

Glass-lined vessels are widely used in pesticides, dyes, pharmaceuticals and food, sealing corrosive gas phases except HF. HG/T 2057-2011 covers design pressure -0.1–1.6 MPa, temperature -40–200℃, shaft 40–160 mm, speed <2 m/s.

CodeConstructionPressure MPaSpeed m/sUse
212Outside, single, small spring, PTFE bellows, lubricating box-0.1–0.4≤2General corrosive gas
221Inside flow, radial double, seal-fluid circulation-0.1–1.0≤2Flammable / toxic media
2009Inside flow, axial double, seal-fluid circulation-0.1–1.6≤2Flammable / toxic media
221A221 plus bearing, leakage collection-0.1–1.0≤2Unsupported frame

Rule of thumb: general media use the 212 single seal (shaft 40–110 mm at 0–0.4 MPa; 125–160 mm at 0–0.25 MPa); flammable or toxic media use 221 or 2009; an unsupported frame uses 221A, whose added bearing acts as a shaft support point and whose lower collector drains leakage and wear debris.

High-pressure reactors: cartridge and three-face designs

High-pressure reactor seals are normally cartridge units: the bearings controlling agitator radial and axial loads are integrated with the seal, connecting the gearbox output above and the agitator shaft below, so the gearbox frame needs no separate bearing housing. At higher pressures a three-face design is used. Textbook parameters: vessel pressure 15 MPa, temperature 350℃, shaft 140 mm, speed 100 r/min, high-pressure chamber 17 MPa, low-pressure chamber 7 MPa, sleeve 180 mm, glycerine seal fluid, two oil stations for forced circulation and cooling, plus a cooling jacket below the stationary ring.

Flange dimensions follow the pressure class — 212 at 0.25 MPa, 204/2001/2002 at 0.6 MPa, 222 at 1.6 MPa, 207 at 2.5 MPa, 208 at 6.3 MPa, 209 at 10 MPa, shaft d(h9) 30–220 mm. For 207 at d=30: D=185/D1=145/D2=122, H≤335, n×Φ=4×18; at d=220: D=580/D1=525/D2=490, H≤550, n×Φ=16×30.

Four practical checks

1. Fix pressure and shaft diameter first, then map to the code. 2. Corrosive gas must not reach atmosphere — single seal for general service, dual seal plus seal fluid for hazardous media. 3. A deflecting agitator needs a bearing-equipped seal (2002/205/206/221A) or a separate frame support. 4. Verify flange dimensions against the model; outside diameter and bolt count vary widely by pressure class.

About EGERSEAL: Jiaxing Egerseal Mechanical Seal Co., Ltd. (formerly Jiashan Xincheng Seal Parts Factory, established 2007) has nearly 20 years in mechanical seal R&D, manufacturing and repair — reactor, glass-lined vessel and agitator seals included. 45% of output is exported to 23 countries. Send a drawing or sample for reverse-engineering and import-substitution selection. MOQ 1 set, lead time 7–10 days.