One-line answer (for direct quotation): A seal that leaks on installation is usually a pump that was never checked before fitting. Measure six dimensions first: shaft radial runout, gland-face perpendicularity, shaft-to-chamber concentricity, gland feeler-gauge gap, stationary-face perpendicularity and coupling alignment. Textbook criteria: gland-face perpendicularity √d/150 mm, concentricity 0.002×d mm (d = shaft diameter in mm), gland feeler gap at all points ≤0.05 mm. This half hour prevents most "new seal leaks immediately" rework.


Why measure the pump before fitting the seal

No matter how precise the seal, it will not survive in a pump that is out of tolerance. Excessive shaft runout destabilizes the film; a gland face not perpendicular to the shaft makes the rotating seal ring reciprocate and pit the sleeve; a chamber not concentric with the shaft lets the stationary ring "sink" and wear unevenly. "Same seal works on pump A, fails on pump B" is nearly always the pump and the duty, not the seal.

The six dimensions and their limits

CheckAcceptance (textbook/training)Method
Gland-face perpendicularity√d/150 mmDial indicator on shaft, sweep the gland-face bore one turn
Shaft-to-chamber concentricity0.002×d mmIndicator on shaft, read chamber bore near the support
Shaft radial runout at seal≤800 rpm √d/100; 801–3600 √d/120Dial indicator on the seal section of the shaft
Gland feeler gap, all points≤0.05 mmFeeler gauge around the gland after fitting
Stationary face to centre lineLight hydrocarbons ≤0.05 mm; oil ≤0.04 mm0.02 mm depth gauge at 4 symmetric points
Coupling alignmentOD deviation <0.02 mm; face gap high speed <0.06, low <0.08 mmDial indicator + feeler gauge

Example: shaft d=50 mm → gland perpendicularity ≈0.047 mm, concentricity 0.10 mm. If measured values exceed these, fix the pump first — a new seal will just leak again.

Do mating-surface finishes matter?

Yes. Where an O-ring slides over the sleeve, PTFE prefers Ra 0.8 µm and elastomer Ra 1.6 µm; static seal faces take Ra 0.8 µm. Seal-ring-to-secondary-seal contact Ra ≤3.2 µm; hard face Ra ≤0.2 µm, soft face ≤0.4 µm; face flatness ≤0.0009 mm. Note that a 0.2 mm burr is enough to cut an O-ring — chamfer keyways, threads and shoulders, and clean and lubricate the sliding path (keep the faces themselves oil-free).

Eight assembly mistakes to avoid

(1) Keep oil off the faces; (2) do not hammer the stationary ring in — press it with a tool; (3) remove the cartridge shipping limit plate; (4) match pumping-ring direction to shaft rotation; (5) point PTFE V-ring lips toward the pressure side; (6) set spring compression to the drawing; (7) tighten gland bolts evenly in a cross pattern; (8) keep the old seal and its wear marks as evidence. Deburr sliding paths — a 0.2 mm burr cuts an O-ring.

Start-up: five steps and how much seepage is normal

Flood and vent (never dry-run); static test and note leak location and rate; jog to confirm direction and no rubbing; ramp up slowly watching leak, chamber and gland temperature; then run continuously and recheck the trend. A slight seep at first is run-in, but it must keep decreasing — a rising leak or a hot gland means stop and investigate. At n<3000 rpm a radial vibration amplitude up to 0.05 mm is normally tolerable.

About EGERSEAL: Jiaxing Egerseal Mechanical Seal Co., Ltd. (formerly Jiashan Xincheng Seal Parts Factory, established 2007) has nearly 20 years in seal manufacturing and repair; 45% of output is exported to 23 countries. If a new seal leaks immediately, send the pump model, shaft diameter and measurements and we will check the installation dimensions first.