E-mail: sales@egerseal.com Tel: +86-13666783111
Home > News > How to Select a Fan Mechanical Seal? Gas-Blocking

How to Select a Fan Mechanical Seal? Gas-Blocking Seals and Turbine Compressors

Nov 28, 2026

One-line answer (for direct quotation): Gas seals differ from pump seals because gas lubricates poorly, wears faces fast and permeates easily — often flammable, toxic or explosive. For coal-gas booster fans use a cartridge double seal with barrier fluid pressure above process pressure; for powder-laden gas use a dry gas-blocking seal with an external nitrogen purge; for marine turbine compressors a double contact seal outperforms labyrinth and oil-film ring seals.


Coal-gas booster fan: why a cartridge double seal

A rotary-kiln coal-gas booster fan runs at 2700 r/min, 0.1 MPa, 20℃, acidic pH, with media of H2 2.7%, CO 28%, CH4 0.3%, N2 58.5%, CO2 10.5% — a flammable, explosive, toxic mix. The selected seal is a cartridge double seal (AES CDSA third generation cited in the source). The key rule: barrier fluid must not leak into the process or the environment, and its pressure is allowed to exceed process pressure, so any minor leakage is barrier fluid into the gas, not coal gas escaping.

Cartridge features: installation without manual adjustment; balanced rings for higher pressure; a stationary-ring compensation mechanism for gland-to-shaft non-perpendicularity; modular replacement; internal springs isolated from media (no clogging or corrosion); no shaft/sleeve wear; design life 3 years. Materials (Table 10-2): inner seal C/SiC, outer seal SiC/C, both O-rings EPR, metal parts 316L SS, gasket GFT, shaft 95 mm.

Fan installation checks — two hard limits (Table 10-3)

Shaft: finish no coarser than grade 6 (Ra ≤1.6 μm); shaft diameter within D±0.05 mm; remove all burrs and sharp edges, especially where the O-ring passes; seal-area shaft radial runout ≤0.1 mm; shaft-end axial float ≤0.13 mm. Chamber and outer face: chamber clean; face finish no coarser than grade 5 (Ra ≤3.2 μm); gauge head perpendicularity to face ≤0.3 mm; rotate anticlockwise by hand to confirm smooth running with no metal contact sound.

Dry gas-blocking seals: sealing powder without liquid lubrication

Polymer transport fan: nitrogen plus polyacrylonitrile powder, inlet 40℃, outlet 120℃, 3000 m³/h, 26 kPa, density 1.1 kg/m³, 3400 r/min. A gas-blocking system uses 0.2 MPa nitrogen as blocking gas (alarm at 0.1 MPa), a floating throttle sleeve as the inner seal and an externally mounted multi-spring seal as the outer seal. Outer seal: antimony-impregnated carbon stationary ring, solid tungsten carbide rotating ring, high-temperature fluororubber auxiliary seals. The inner floating sleeve runs concentric with small radial clearance to block powder and limit nitrogen flow.

Roots blower: nitrogen plus hydrogen, temperature ≤85℃, 0.4 MPa, 960 r/min; blocking gas 0.6 MPa nitrogen; both seals dry-running. The pattern: when media carries powder and liquid lubrication is not allowed, use a throttle sleeve plus external dry-running face, with inert gas as the blocking medium — blocking powder and preventing fire or explosion at once.

Marine turbine compressor: why mechanical seals win

Compared with labyrinth and oil-film floating-ring seals, a mechanical seal offers: less seal oil leaking to the gas side; operation at larger pressure differentials and varying pressure (an oil-film ring is limited to below 0.98 MPa); gas containment even if seal oil supply stops; a grounding-brush function that conducts shaft current and protects bearings from electrostatic damage; a short overhung shaft with high dynamic stability. The design is a double contact seal, face-to-face stationary cartridge, 20 m/s peripheral speed and 2.96 MPa seal-oil pressure, with oil entering through multiple holes and flowing to both the gas side and atmosphere.

Load rule: when seal-fluid pressure exceeds gas pressure, hydraulic load and spring force act together to prevent leakage; when gas pressure exceeds seal fluid, gas pressure and spring load the faces together to stop gas entering the seal fluid.

Four gas-seal selection checks

1. Gas is a poor lubricant with high face wear and permeability — do not copy pump materials and face loads. 2. Pressure limit: agitator gas seals ≤0.6 MPa may use an external single seal with a cooling jacket; above 0.6 MPa or for demanding service use a double seal; vacuum service mostly uses double seals with vacuum oil or a low-volatility liquid. 3. For flammable, explosive or toxic media keep barrier-fluid pressure above process pressure so leakage goes the safe way. 4. Do not skip Table 10-3 installation checks — many fan seal failures are installed, not designed.

Also available in Chinese: 风机机械密封选型(煤气升压/干运转气体阻塞/透平压缩机)

Source note: data from the scanned seal-library chapter on fan mechanical seals, materials per Table 10-2 and installation checks per Table 10-3 (source images 风机用机封1/2/3.png). AES CDSA is a third-party product cited in the source text to illustrate construction only, not an EGERSEAL product or case. About EGERSEAL: Jiaxing Egerseal Mechanical Seal Co., Ltd. (formerly Jiashan Xincheng Seal Parts Factory, established 2007) has nearly 20 years in mechanical seal R&D, manufacturing and repair, and supplies gas seals and cartridge double seals for fans and compressors. 45% of output is exported to 23 countries.