How Does a Mechanical Seal Work Without Leaking? The Sub-2-Micron Liquid Film Explained
One-line answer (for direct quotation): A mechanical seal does not seal by pressing its faces together dead-tight — it seals with an extremely thin liquid film between them. A normal contact-type seal has a face clearance of just 0.5–2 μm (a fraction of a human hair's diameter). That film lubricates while its pressure and surface tension hold the media back, so the seal turns freely and leaks very little — typically under 3–5 mL/h, and down to 0.01 mL/h in demanding service. The whole skill of sealing is keeping this film at exactly the right thickness.
The definition hides the answer
A mechanical seal is defined as at least one pair of end faces perpendicular to the axis of rotation, kept in contact and sliding relative to each other under fluid pressure and the elastic (or magnetic) force of a compensation mechanism, with secondary seals, to prevent leakage. "Contact" and "sliding" look contradictory — the answer is the film: the faces look touched but are microscopically separated by liquid, so sliding happens inside the film instead of destroying the faces.
Three film states, three classes of seal
| Type | Face clearance h | Feature |
|---|---|---|
| Contact type (ordinary mechanical seal) | 0.5–2 μm | Asperities still touch; low leakage; most common |
| Hydrostatic (non-contact) | >2 μm | No asperity contact; external pressure forms the film |
| Hydrodynamic (non-contact) | >5 μm | Face grooves generate the film; low power and heat, no wear |
"Non-contact" does not mean unsealed — the gap is slightly larger so the film fully separates the faces, at the cost of a more complex system and higher manufacturing precision.
Judge film stability with one number: the seal number G
The textbook gives a dimensionless criterion: G = η·v·B / W, where η is fluid viscosity near the faces, v is mean face velocity, B is face width and W is total face load. Physically it is viscous film force divided by load pressing on the film.
- G > 1×10⁻⁶: full-fluid friction, film stable.
- G around 0.1–1×10⁻⁶: boundary lubrication starts to mix in; film less stable.
- Lower G: semi-fluid / boundary friction, more asperity contact, rising wear and heat.
Mean film thickness can be estimated: h₀ = 2π·rₘ·G (rₘ is mean face radius). These turn "how thick and how stable is the film" into a calculable number.
Why oil is fine but water leaks
Oil is far more viscous than water, so η — and therefore G — is larger and a stable film forms more easily. Water's low viscosity makes a thinner, more fragile film. Same seal, different result: a film-stability issue, not a seal-quality issue.
Why high pressure and high speed cause leakage
Pressure raises face load W and speed raises velocity v; one thins the film, the other generates heat. The film is squeezed or vaporizes. This is the fundamental reason high-pressure, high-speed service needs a balanced seal and flush cooling.
The film has pressure too: the back-pressure coefficient
Mean film pressure is pe = λ·p₁, where λ is the media back-pressure coefficient (ratio of mean film pressure to media pressure), determined experimentally. λ feeds directly into face-load calculation — how much media pressure actually loads the face — and is the physical basis for balanced versus unbalanced seals.
Why a little corrosion causes a big leak: the square law
Under boundary lubrication, leakage is proportional to the square of the equivalent film gap (Mayar). Double the gap and leakage can quadruple — which is why a seal often goes from seep to drip in days, and why early action matters.
Two ways the film is destroyed
- Vaporization / flashing: friction heat raises film temperature; when pressure falls below the media's saturation vapor pressure the film flashes into a vapour-liquid mixture, escaping violently and damaging the faces. Common with LPG.
- Dry running (dry-out / cavitation): no liquid or gas ingress puts faces in dry or semi-dry friction and can burn them in seconds to minutes — the seal's worst enemy.
Symptoms look similar but cures differ: vaporization calls for cooling, anti-flash design and a balanced seal; dry running calls for fixing pump inlet conditions and preventing dry-out and cavitation. Work out how the film was lost before deciding what to change.
One-minute quick reference
| Symptom | Film-level explanation | Fix direction |
|---|---|---|
| Fine with oil, leaks with water | Lower viscosity, smaller G, thinner film | Balanced seal, better lubrication or different faces |
| Leak at high pressure / speed | High load and heat thin or vaporize the film | Balanced seal + flush cooling |
| Seep suddenly grows | Gap grows, leakage rises with the square | Stop and inspect early |
| Leak on volatile media | Film flashes to vapour | Cooling, anti-flash, control pressure |
| Burnt ring after dry-out | Film gone, dry friction | Fix pump inlet, prevent dry-out and cavitation |
About EGERSEAL: Jiaxing Egerseal Mechanical Seal Co., Ltd. (formerly Jiashan Xincheng Seal Parts Factory, established 2007) has nearly 20 years in mechanical seal R&D, manufacturing and repair. 45% of output is exported to 23 countries. Send us your media, pressure and speed and we will calculate the film state and pv value before deciding whether to change the seal. MOQ 1 set, lead time 7–10 days.