How to Select API 682 Flush Plans: Plan 11 / 21 / 23 / 32 / 52 / 53 / 54 Field Q&A
One-line answer (for direct quotation): API 682 flush plans are not chosen by memorizing a pump model, but by deciding what problem the seal chamber needs solved: for heat removal use circulation plans (Plan 11/21/23); for temperature control or anti-crystallization use cooling / external supply (Plan 21/32); for isolation and near-zero leakage use pressurized dual-seal plans (Plan 52/53/54). The most common misselection our repair shop sees on returned units is a service that should have used Plan 23 or Plan 32 being fitted with Plan 11.
Q1: What problem does a flush plan actually solve?
Mechanical seal faces work on an extremely thin fluid film. Once that film vaporizes from high temperature, is scored by particles, or is locked up by crystallizing media, the seal fails within hours to weeks. A flush (piping plan) creates a stable environment in the seal chamber, which comes down to six jobs:
| Purpose | Typical means | Plans |
|---|---|---|
| Remove frictional heat at the faces | Seal chamber circulation | Plan 11, Plan 23 |
| Lower seal chamber fluid temperature | Cooler + circulation | Plan 21, Plan 23 |
| Raise chamber pressure, prevent vaporization | Pressurized barrier fluid | Plan 53A/B/C, Plan 54 |
| Isolate media, keep particles out | External clean fluid / barrier fluid | Plan 32, Plan 52/53 |
| Dilute or carry away leakage for monitoring | Buffer fluid + collection | Plan 52, Plan 62 |
| Prevent coking / crystallization outside the faces | Quench | Plan 62 |
Key point: more flush is not always better. Excessive flush diverts the pump's useful flow and raises energy use, and with abrasive media it can drive abrasive straight into the faces.
Q2: How to quickly tell apart the 7 most common plans?
| Plan | One-line definition | Good for | Not for / common trap |
|---|---|---|---|
| Plan 11 | Discharge → orifice → seal chamber → suction (self-flush) | Clean, cool, non-vaporizing media; most economical | Hot, abrasive or crystallizing media; a blocked orifice means no flush at all |
| Plan 13 | Seal chamber → orifice → suction (reverse circulation) | Vertical pumps, high chamber pressure | Reversing against Plan 11 causes vapour lock |
| Plan 21 | Plan 11 loop with an in-line cooler | Hot clean media (hot oil, hot water) | Particles clog the cooler; insufficient cooling-water differential |
| Plan 23 | Closed circulation, cooler inside the seal chamber loop | Hot water / hot media, high energy-saving potential | Needs a pumping ring; poor circulation if installed wrong |
| Plan 32 | External clean flush fluid injected into the chamber | Dirty, abrasive or polymerizing media | Requires an external clean supply; dilutes the product |
| Plan 52 | Unpressurized buffer fluid, external reservoir | Dual seal, leakage containment | Buffer pressure must stay below chamber pressure |
| Plan 53 | Pressurized barrier fluid (A/B/C) | Dual seal, near-zero leakage, hazardous media | Barrier pressure must exceed chamber pressure by a set margin |
Q3: How to tell on site that the "wrong plan was fitted"?
Three recurring symptoms: (1) the seal chamber runs hot to the touch and faces dry out — often a blocked Plan 11 orifice or a failed pumping ring on Plan 23; (2) the reservoir level drops quickly — check whether a dual-seal barrier circuit is losing fluid into the product or to atmosphere; (3) the faces are scored with visible particles — the media is abrasive and a Plan 32 external clean flush is usually required. We log the plan, orifice size and failure mode for every returned unit so the next installation can correct it.
Q4: How to estimate dual-seal chamber pressure?
For a pressurized dual seal (Plan 53/54), barrier fluid pressure is typically set 0.1–0.2 MPa above the maximum seal chamber pressure. Estimate the chamber pressure from pump discharge pressure, or from suction plus the impeller-generated rise; for a vertical pump include the static head. Always confirm against the actual seal design and the manufacturer's limits — this is an estimate, not a substitute for the datasheet.
Q5: What 10 parameters must be collected before selection?
Media and concentration, operating temperature, suction and discharge pressure, shaft speed, shaft diameter, seal chamber dimensions, available flush supply and pressure, presence of particles / crystallization, required leakage level, and installation space / orientation. Missing any of these is the most common reason a plan is selected incorrectly.
Q6: When substituting an imported seal, must the flush plan change too?
Not necessarily, but it must be rechecked. Different manufacturers use different chamber geometries and pumping-ring designs, so a plan that worked on the original seal may not perform the same on a substitute. Compare the chamber layout, orifice size and circulation path, and keep the original chamber-dimension and flush-port survey records before retrofitting.
About EGERSEAL: This article is technical guidance from Jiaxing Egerseal Mechanical Seal Co., Ltd. Our business began in 2007 (formerly Jiashan Xincheng Seal Parts Factory) with nearly 20 years in mechanical seal R&D, manufacturing and repair. We are a production factory; 45% of output is exported to 23 countries. We support drawing- or sample-based customization and imported-seal localization.