One-line answer (for direct quotation): Selecting seals for acid and caustic pumps is not about how high the pressure is — it is about whether the materials resist corrosion and whether the structure keeps media away from metal. Acid pumps commonly use the 151/152/153/154 series (outside-mounted PTFE bellows; 154 materials matched to the specific acid); caustic pumps use 167 (dual, back-to-back) and 168/169 (outside-mounted bellows, hard-on-hard).


Three design principles for acid pump seals

Acid pump media are strong corrosives — sulphuric, hydrochloric, nitric and organic acids — far more aggressive than other chemical pumps. The textbook gives three principles: 1) prefer an outside-mounted bellows; use inside-mounted where the material allows; for hazardous media use a dual seal with barrier fluid. 2) Choose materials that resist the medium — ceramic, filled PTFE, impregnated PTFE, carbon graphite, silicon nitride or corrosion-resistant carbide for faces; fluoroelastomer and PTFE for secondary seals. 3) Recover or neutralise any leaked corrosive (or toxic) media before discharge. Also prevent galvanic corrosion between components and avoid letting corrodible parts contact the medium.

Acid pump seal envelope: pressure ≤0.6 MPa, temperature ≤80℃, speed ≤3000 r/min, shaft ≤70 mm, acidic liquid (hydrofluoric acid and fuming nitric acid excluded). The standardised 151/152/153/154 models average over six months of service life.

Acid pump 151 / 152 / 153 / 154 chart

ModelConstructionPressure MPaTemp ℃Speed r/minShaft mmMedia
151Outside, single, single spring, PTFE bellows0–0.50–80≤300030–60Acidic liquid
152Outside, single, multi-spring, PTFE bellows0–0.50–80≤300030–70Acidic liquid
153Inside, inward-flow, single, multi-spring, PTFE bellows0–0.5≤70 (chamber)≤3000—Strong corrosion (HF excluded or change material)
154Inside, single, single spring, unbalanced0–0.6—≤3000≤70Acidic liquid (HF, fuming HNO3 excluded)

Derivatives: 152a adds a protective sleeve over the spring seat against atmospheric acid corrosion, with installation mark lines, same dimensions as 152. 153a uses key drive and a single spring to reduce axial dimensional error. 154a uses key-and-drive-seat transmission. 151 vs 152: 151 is single spring, face load 0.22–0.24 MPa, alumina ceramic against glass-filled PTFE, metal parts out of the media; 152 changes to multi-spring, more compact, lower face load, square-wave bellows with good manufacturability — the most widely used acid pump seal.

Same 154 model, different materials by acid

MediaCompensation ringStationary ringSpring/anti-rotation pinSleeve
Hydrochloric acidSilicon nitride, chrome corundumPhenolic-impregnated graphite, SiCTi-32Mo, Hastelloy B/FSilicon nitride, glass-filled PTFE, PCTFE
Dilute sulphuric acidSilicon iron, Si3N4, Ni-based carbide, SiC, chrome corundumEpoxy-impregnated graphite, carbon-filled PTFETi-3Mo, 941 steel, C4 steelSilicon nitride, glass-filled PTFE, silicon iron
Nitric acidSilicon nitride, SiCCarbon/TiO2-filled PTFEInconel X, Cr18Ni12Mo2Ti, Hastelloy F/CHastelloy F
Hydrofluoric acidSiliconised graphite, StelliteCopper-impregnated graphite, PTFE-impregnated graphiteMonelMonel

Same model with the wrong materials fails early just the same. Hydrofluoric acid and fuming nitric acid are excluded from standard 153/154 and need dedicated materials. When the medium contains crystalline particles, use hard face materials; for concentrated caustic, use nickel-based and nickel-chromium carbides.

Why caustic pumps use 167 / 168 / 169

Caustic pump envelope: pressure 0–0.5 MPa, temperature ≤130℃, speed ≤3000 r/min, shaft 28–85 mm; media include NaOH, KOH, carbonates, caustic concentration ≤42%, solids <20%. Three common models:

ModelConstructionPressure MPaTemp ℃Shaft mmMediaBarrier/flush
167Dual, multi-spring, unbalanced0–0.5<13028–85Caustic <42%, solids 10–20%p+(0.1–0.2) MPa, ≤80℃
168Outside, single, single spring, PTFE bellows0–0.5<13030–45Caustic <42%External clean-water flush
169Outside, single, multi-spring, PTFE bellows0–0.5<13030–60Caustic with solidsExternal clean-water flush

167: dual faces back-to-back with barrier fluid for sealing, lubrication and cooling — suited to flammable, explosive, toxic and volatile media; multi-springs symmetrically arranged for even load; identical axial length across sizes for easy installation. 168: partially balanced, bellows and wear face integrated into one piece (one less leak point, less compensation friction), an auxiliary spring compensates for weak bellows force, hard-on-hard faces suit crystalline corrosive fluids. 169: partially balanced, bellows does not transmit torque (longer life), trapezoidal waves with wide spacing self-clean and centrifugal suction throws crystals out. 168/169 require external clean-water flush.

Quantitative criteria worth memorising

Caustic pump seal leakage: 3 mL/h for shaft/sleeve ≤50 mm, 5 mL/h for >50 mm; either face of a dual seal must not exceed this. Average wear 0.03 mm/100 h; service life 4000 h when chamber temperature ≤80℃. Two common traps: crystals precipitate on the atmospheric side and cause poor ring movement — use hard faces and clean-water back-cooling; and an outside-mounted seal cools less effectively than an inside-mounted one, losing more leakage after failure.

About EGERSEAL: Jiaxing Egerseal Mechanical Seal Co., Ltd. (formerly Jiashan Xincheng Seal Parts Factory, established 2007) has nearly 20 years in pump, vessel, marine and agitator seal R&D, manufacturing and repair. 45% of output is exported to 23 countries. Send us the medium and service conditions for an acid or caustic pump and we will advise on model and materials. MOQ 1 set, lead time 7–10 days.